System Programming
for the AD1650B
MicroPower EP System
Programming and Operating Instructions
This manual describes the system programming and operating procedures for the American Dynamics AD1650B MicroPower EP
Matrix Switching System. The AD1650B MicroPower EP is a CCTV surveillance system for multiple video inputs, multiple
video outputs, and multiple control stations. The AD1650B is capable of controlling a maximum of 128 video input sources such
as cameras and a maximum of 16 video outputs such as monitors and video tape recorders. Menu-driven programming is
provided on the AD1650B for most system setup operations. Non-menu setup of monitor display format, camera preset scenes,
alarm arming/disarming, and individual Monitor Tours are provided using keyboard commands.
Zobrazit stránku 0
1 2 3 4 5 6 ... 63 64

Shrnutí obsahu

Strany 1 - MicroPower EP System

System Programmingfor the AD1650BMicroPower EP SystemProgramming and Operating InstructionsThis manual describes the system programming and operating

Strany 3

2-1Keyboard ControlThis section of the manual describes the standard AD1650B system videoswitching and control capabilities that are provided from an

Strany 4

KEYBOARD CONTROLKeyboard Passcode EntryPasscode entry is a security procedure to allow only authorizedpersonnel to operate the AD1650B system. When U

Strany 5 - MICROPOWER CONTROL SYSTEM

Keyboard Video SelectionNote: Keyboard video selection is available from any ADkeyboard connected to the AD1650B. The keyboardcontrol functions desc

Strany 6

Controlling Camera Site FunctionsCamera site control functions (pan/tilt, motorized lens, presetscenes, and auxiliary actions) are available at the ke

Strany 7 - System Operation

Running a TourA Tour sequentially displays a selected series of camera videoinputs on a single monitor. A single tour sequence may display64 separate

Strany 8

Calling a System SalvoA System Salvo is a group of cameras that can be called forsimultaneous display on a contiguous group of monitors.System Salvos

Strany 9

3-1Non-Menu ProgrammingThis section of the manual describes the AD1650B system non-menuprogramming capabilities. These setup operations are accessed

Strany 10

NON-MENU PROGRAMMINGThe following non-menu setup programming functions areaccessible from AD1678CM or AD2078 keyboards only.NOTE: The keyswitch must

Strany 11 - Keyboard Control

Monitor Display ArrangementThe arrangement of the titles, date, and time in the monitor on-screen display (Figure 2-1) may be changed by keyboardcomma

Strany 12

This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not tobe copied or disclosed in any manner

Strany 13

Programming Monitor ToursA Tour sequentially displays a selected sequence of cameravideo inputs on any monitor. A Monitor Tour is a temporarysequence

Strany 14

Arming MonitorsSystem monitors are armed using a Monitor Arming Codewhich identifies the alarm Display method (Single, Block, orDual monitors), Queuin

Strany 15

Programming Alarm ContactsNote: The following contact programming procedures are forAD1678CM keyboards only. For other keyboards, usethe Monitor/Con

Strany 16

4-1Menu ProgrammingThis section of the manual describes the AD1650B menu programmingcapabilities.Menu Programming...

Strany 17 - Non-Menu Programming

MENU PROGRAMMING All the features of the AD1650B are programmable using on-screen menus. The menus are displayed via a separate videooutput (labeled

Strany 18

Menu Cursor Positioning/PagingThe following cursor instructions apply to all menus.To position the cursor to a desired location on the menu:• Use the

Strany 19

SET TIME AND DATEThe SET TIME AND DATE menu permits setting the dateformat, date, time, and day of the week for on-screen displays.DATE FORMAT - Sele

Strany 20

SET SYSTEM TOURSA System Tour is a programmable sequence of cameras thatcan be called by a user to be displayed on the called monitor,or called by Ev

Strany 21

PROGRAMMING A SYSTEM TOURTo select a System Tour for programming:1. Move the cursor to the TOUR number line of the menu.2. Enter the desired tour numb

Strany 22

CN (Connect Next)If a salvo or tour switching is desired at a tour entry:1. Move the cursor to the CN column and desired entry line.2. Press the ACK k

Strany 23 - Menu Programming

CONTENTSPageDESCRIPTION... 1System Features ...

Strany 24

SET SYSTEM SALVOSA System Salvo is a group of cameras that can be calledsimultaneously to a contiguous group of monitors. A salvo canbe called by key

Strany 25

PROGRAMMING A SALVOTo select a System Salvo for programming:1. Position cursor to the SALVO line in the menu. 2. Enter the desired salvo number (from

Strany 26

SET EVENT TIMERSEvent Timers permits automatic callup of System Tours and/orAlarm Monitor Contact Tables. Each one of the automaticcallups is referred

Strany 27

Alarm Monitor/Contact (ALM ) callupSeparate Monitor/Contact Tables can be programmed to definewhich alarm contacts are armed for each monitor in the s

Strany 28

SET ALARM CONTACTS The SET ALARM CONTACT menu is used to associatecameras to contacts. A maximum of 512 entries are allowed.Each Alarm Contact Number

Strany 29

PROGRAMMING ALARM CONTACTSAlarm Contact Numbers 1 to 128, 129 to 256, 257 to 384, and385 to 512 are defaulted to cameras 1 through 128,respectively.

Strany 30

CN (Connect Next)For salvo switching on alarm contact receipt:1. Position the cursor to the desired CN column and ACN.2. Press the ACK key to cycle th

Strany 31

MONITOR STATUSThe MONITOR STATUS display provides information aboutthe 16 monitors connected to the system.This display has two pages, with eight moni

Strany 32

MONITORThe MONITOR menu is used to review and change eachmonitor's setup programming.To select a Monitor for review or programming:1. Place the c

Strany 33

## (Block number) - The block number field associatesmonitors together to form a monitor “block” for alarm callup.A monitor block may consist of any

Strany 34

CONTENTSPageMENU PROGRAMMING... 4-1Main Selection Menu...

Strany 35

CAMERA MENUThe CAMERA menu is used to re-assign camera numbers andto program camera titles. Each selection of the CAMERAmenu calls up another menu, s

Strany 36

TITLEThe Camera TITLE menu is used to program a 16-characteralphanumeric title for each camera, for inclusion in the on-screen display.To select a cam

Strany 37

PORTThe PORT menu is used to configure baud rates, data bits,parity, stop bits, and port use for each of the four RS-232 portson the rear of the AD165

Strany 38

PORT USE TypesALARM - Used for an Alarm Interface Unit connection for input of alarm codes to the AD1650B. Each alarm event messagesent to this port

Strany 39

ACCESSThe ACCESS menus define system partitioning which controlsoperator keyboard access to monitors, cameras, pan/tilts, andalarms. System partition

Strany 40

KEYBOARD/MONITORThe KEYBOARD/MONITOR menu defines the Keyboard-to-Monitor access which prevents selected keyboards fromcalling selected monitors. The

Strany 41

KEYBOARD/CAMERA VIEWThis menu defines the Keyboard-to-Camera viewing access,which prevents selected keyboards from calling up selectedcameras for view

Strany 42

KEYBOARD/CAMERA CONTROLThis menu defines the Keyboard-to-Camera control accesswhich prevents selected keyboards from controlling remotefunctions on se

Strany 43

MONITOR/CAMERA ACCESSThis menu defines the Monitor/Camera access which preventsselected monitors from viewing selected cameras.In this menu it is the

Strany 44

MONITOR/CONTACT ACCESSThe MONITOR/CONTACT ACCESS menu defines whichalarm contacts are associated to each monitor in the system.Five Monitor/Contact Ta

Strany 45

SYSTEM FEATURESVideo Switching Control: The AD1650B controls videoswitching of all camera inputs and all monitor outputs in theswitching system. Swit

Strany 46

PRIORITY MENUThe PRIORITY menu is used to:• Enable (or disable) user identification passcode entry intothe system, • Configure each of the eight prior

Strany 47

SET USERIf USER IDs is enabled, the SET USER menu is used to set apriority level and passcode for each of 48 users. Each prioritylevel is defined thr

Strany 48

SET PRIORITYThe SET PRIORITY menu is used to define the configurationfor each of the eight priority levels. All levels default to thesame configurati

Strany 49

AppendixSystem Defaults... A-2Alarms ...

Strany 50

AD1650B SYSTEM DEFAULTSThe following are the factory default values; these are set from the System Reset function, page 1-3 or 3-2.Keyboard ControlAll

Strany 51

ALARMS - PROGRAMMING OVERVIEWAn ALARM is a signal generated by an external device that isconnected to an AD Matrix Switching System, either directly

Strany 52

ALARMS - MONITOR ARMING CODEThe Monitor Arming Code identifies the alarm Display,Queuing, and Clearance methods for the monitor.Alarm Display Methods

Strany 53 - Appendix

ALARMS - ARMING NOTESAssociating Alarms with Camera SalvosEach alarm contact may be associated with a camera salvo forcallup when the alarm is receiv

Strany 54

ALARMS - MONITOR ARMING CODES - ARM TYPESThe following are the available Monitor Arming Codes for theAD1650B. Each is identified by the code number,

Strany 55

BLOCK Display, HOLD Queuing(10) BHI - Multiple monitor alarm block, all armed/alarmedcontacts are queued and displayed on monitors with noexisting al

Strany 56

System Status Display: The current camera-to-monitorswitching assignments can be displayed by operator request.This display includes the current statu

Strany 57

ON-SCREEN STATUS LINE DISPLAYSSetup/ProgrammingThe following messages appear in the monitor on-screen StatusLine during certain non-menu programming f

Strany 58

A-9AD1650B APPENDIXAmerican Dynamics KeyboardsKeyboard AD2078,Model NumberAD1678C AD1678CE AD1678CM AD1678CME AD1677 AD1677E AD1676B AD1676BE AD1672AT

Strany 59

REMOTE COMPUTER CONTROLThe four AD1650B RS-232 control ports use asynchronous,full duplex, RS-232C protocol. As shipped, all ports are set foroperati

Strany 60

AUXILIARY KEY CODE FUNCTIONSF1 - Special function key:1 F1 - Unlocks the current camera2 F1 - Locks the current camera99 F1 - Logoff from passcode

Strany 61

An American Dynamics ProductDesigned and built bySensormatic CCTV Systems DivisionOne Blue Hill PlazaPearl River, New York, 10965(914) 624-7600Technic

Strany 62

1-1System OperationThis section of the manual provides an overview of the system operationand setup programming functions.System Operation . . . . .

Strany 63

SYSTEM OPERATIONThe AD1650B Central Processing Module controls all MatrixSwitching System operation and provides programming menusfor AD1650B System s

Strany 64

System Reset Following initial AD1650B system installation or a major re-configuration of the switching system, it may be necessary toclear all progra