American Dynamics SpeedDome Optima Instalační příručka

Procházejte online nebo si stáhněte Instalační příručka pro Bezpečnostní kamery American Dynamics SpeedDome Optima. American Dynamics SpeedDome Optima Installation guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 18
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
1
SpeedDome Optima Indoor Installation Guide
RASI Series
2
Before performing these steps, ensure power is off and
read additional information attached for important
details and warnings!
Using the template
supplied, cut a hole in
the ceiling.
Adjust all four “swing
out” mounting clips for
the ceiling thickness..
8000-2692-01, Rev. F
Page 1 of 18
3
4
Attach cable connectors.
Ensure power is off.
Use screwdriver
supplied to tighten
connector screws. DO
NOT over tighten the
connectors!
Place cover
on housing.
Secure cable to
housing using the
cable tie supplied.
If running cables through
conduit (not shown), remove
appropriate knockout (1/2in
Or 3/4in), and connect
conduit to the cover.
If running cables direct
(shown), attach the clamp
and nut assembly supplied to
one of the 1/2in knockouts in
the side of the cover.
Video
Power
(Green)
Data
(Black)
On Cable
1
RS422
SensorNet
Manchester
NC
C
NO
*AR
*AI
R+
R–
T+
T–
+
1
1
~ (AC)
~ (AC)
GND
BLK
RED
WHT
ORG
GRN
YEL
BRN
ORG
YEL
Input Output
BLK
WHT
Alarm
(Grey)
Cable
hookup
A
D
B
C
Set the dome address and
terminate the dome, if
necessary.
The camera/motor assembly is shipped
terminated” (switch to left) for when it is installed
at the end of a data cable. Should the cable
continue to another dome, move the slide
switch to the right to “unterminate”.
A
B
Terminate
Switch
Address Switches
7
1
SW3 SW2 SW1
x100 x10 x1
The address range is from 001 to 255,
except for Manchester, which is 01 to 64.
Set switches. Example: For address 107,
set SW3 to 1, SW2 to •, and SW1 to 7.
T
Zobrazit stránku 0
1 2 3 4 5 6 ... 17 18

Shrnutí obsahu

Strany 1 - RASI Series

1SpeedDome Optima Indoor Installation GuideRASI Series2Before performing these steps, ensure power is off and read additional information attached for

Strany 2

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 10 of 18 Troubleshooting If a failure cannot be easily fixed externa

Strany 3 - RASO Series

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 11 of 18 Illustrated Parts List Not all of the parts, which are show

Strany 4 - SW3 SW2 SW1

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 12 of 18 Outdoor Housing Indoor/Outdoor Housing Assy. 0400-1208-01

Strany 5 - Housing

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 13 of 18 Camera/Motor Assembly 18 20 19 22 21 17 14 15 16 Tilt A

Strany 6 - Warnings and Cautions

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 14 of 18 Base Assy. 0400-1203-01 14 Bearing, Pan 2510-0040-01 15

Strany 7 - Connector Pin Assignments

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 15 of 18 Specifications Operation Manual pan speed...

Strany 8 - Cable Requirements

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 16 of 18 Electrical Power Line Input voltage...

Strany 9 - Synchronizing Domes

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 17 of 18 Alarm Input Provides signal input to dome alarm. Connector

Strany 10 - Troubleshooting

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 18 of 18 Declarations Regulatory Compliance Emissions ...

Strany 11 - Illustrated Parts List

8000-2692-01, Rev. FPage 2 of 185S S 67Secure the housing to a strong structural ceiling member.Secure the housing to the ceiling.Attach the bubble to

Strany 12 - Outdoor Housing

1SpeedDome Optima Outdoor Installation GuideRASO Series2= Step PreventsBefore performing these steps, ensure power is off and read additional informat

Strany 13 - Camera/Motor Assembly

45BAttach bubble to housing.Set the dome address and terminate the dome, if necessary.Loosen three captive screws and push in all three tabs simultane

Strany 14 - Base Assy. 0400-1203-01

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 5 of 18 SpeedDome® Optima Housing Continuation of Installation Info

Strany 15 - Specifications

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 6 of 18 Warnings and Cautions Please review the following warnings a

Strany 16 - Electrical

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 7 of 18 Preventing Condensation in Outdoor Domes Damage, missing pa

Strany 17 - Environmental Specifications

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 8 of 18 Cable Requirements Data Cable The table below shows requirem

Strany 18 - Declarations

SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F CONTINUATION OF INSTALLATION GUIDE 9 of 18 Worst-Case Meters Low Line V (Feet)117 130 (425)100 80 (250)

Komentáře k této Příručce