Model AD1273 CobraDome Indoor Surveillance UnitInstallation and Operation InstructionsThis manual describes the installation and maintenance procedure
SETUP AD12734SETUPThis section describes the required settings for properoperation of the AD1273. Before installing the AD1273,determine the intended
OFFON12345678S1CHASSISThunbwheel Switch (2)DIP Switch4 5Tens DigitUnits DigitFigure 3 - DIP Switch Setting LocationsAD1273 SETUP5
Camera Number AssignmentFor individual control of camera pan/tilt functions by a matrixswitching system, an individual camera number must beassigned t
AD1273 SETUP7CHASSIS4 5Tens DigitUnits digitFigure 4 - Camera Identification Thumbwheel Switches
Dome ConfigurationsWhen using the AD1273 with other domes in a securitysystem, determine the type of configuration that best suits theparticular appli
Jumper RemovalTo remove the J2 jumper from the AD1273 printed circuitboard:1) Disconnect all data, video, and power connections from thedome.2) Remove
CONNECTIONS AD127310CONNECTIONSData Line Connections Data line connections to the AD1273 are made with user-supplied, 2-wire twisted pair, shielded, B
11Power ConnectionsThe 24VAC power lines enter the AD1273 through a 7-pinPlug and Ramp connector (see Figure 9). The 7-pin Rampconnector is mounted t
12INSTALLATION AD1273INSTALLATIONDrop Ceiling MountThe weight of the AD1273 unit requires additional support ofthe dropped ceiling grid. This additi
AD1273 INSTALLATION13Building FrameSafetyChainChassisHousing Safety WiresSafety WiresDrop Ceiling Tileor2 ft. x 2 ft. Custom TileDropCeiling GridRunne
The software/firmware furnished with this equipment is confidential to, and copyrighted by, AMERICAN DYNAMICS. It isnot to be copied or disclosed in
INSTALLATION AD127314Direct and Remote Hard MountDirect hard mounting refers to bolting the AD1273 housingdirectly to a ceiling. Remote hard mounting
Figure 14 - Remote Chassis Housing-to-Ceiling Hard MountExisting CeilingIncoming Data, Video, and24VAC Power HarnessIncoming Data, Video, and 24VAC Po
Pendant MountMounting the AD1273 in a pendant configuration requiresusing a pipe flange bolted to the chassis housing, a length ofpipe determined by t
Mounting SurfaceIncoming Data,Video, and 24VAC Power HarnessSafety CablePendant Shroud *Pendant ShroudFascia Plate *1 1/4" Mounting Pipe(User su
INSTALLATION AD127318Chassis InstallationPrior to installing the chassis in the chassis housing, set the 8-position DIP switch and the camera number t
Chassis(Only the Frame is Shown for Clarity)Squeeze togetherSqueeze togetherDetail A: Chassis Mounting Pin Positive EngagementMounting Pin SocketMount
INSTALLATION AD1273Lower Dome InstallationAlign the viewing port (clear area) of the lower dome with thecamera lens.NOTE: Prevent fingerprints accumul
21Fascia Plate Installation1) Push the plastic safety lanyard attached to the fascia plateinto the lanyard tab slot on the chassis frame. The tab mu
INSTALLATION AD127322Pendant Shroud InstallationThis procedure applies only to pendant installations using thependant shroud. These instructions comp
23AD1273 INSTALLATIONMounting SurfacePendant ShroudFascia Plate *Pendant Shroud *Machine Screws (4)ChassisHousingCompletedInstallationFigure 19 - Pe
The installation of this product should be made by qualifiedservice personnel and should conform to all local codes.QA301CWarning: This product gener
OPERATION AD1273OPERATIONThe AD1273 Series dome uses AD Manchester Control Codefor pan/tilt positioning, camera zoom, camera focus, and lensiris funct
AD1273 OPERATION25ENTER6 41234567890CLEARAUXILIARYIRISFOCUSZOOMENTEREXITPAGEPAGEOFF ONCLOSE OPENNEAR FARW ID E TE LECAMERA1 0 2 4LAST B-PAS ACKNEXT RU
OPERATION AD1273Special CommandsThe following is a list of special AD Manchester Control Codecommands available to the AD1273.RESET DOME - (65 CALL th
27Keyboard Command1 - 64 Set Shot1 - 64 Call Shot65 Call, then, 65 Set66 Call, then, 66 Set67 Set67 Call68 Call69 Call68 Set71 Call, then, 69 Set70 Se
ADJUSTMENTS AD127328ADJUSTMENTSBacklash AdjustmentProper backlash adjustment eliminates any apparent videoimage hesitation during a slow pan rotation
29ChassisCameraHousingPan GearPan Gear BevelPan AxisDrive MotorPan MotorDrive Gear Pan AxisDrive Gear#73 Twist DrillPan MotorMounting BracketFigure 2
30Lens Tracking AdjustmentWhen connected to a monitor, the image generated by theCobraDome camera must stay in focus during transitions fromtelephoto
31AD1273 ADJUSTMENTSCamera LensFocus RingLens TrackingAdjustment WheelTilt AxisDrive GearCobraDomeChassisPan AxisDrive GearCameraLens Frame8-Position
Appendix
18 AWG Twisted Pair, Shielded,Belden 8760 or EquivalentNOTE: These Connections Are Typical of One Data Distribution UnitWBSSWBACTP800212 VOLTS AC10 VA
AD2150 Matrix ControllerRS232 PORTS123KEYBOARDS2345CAMERASALARMS RELAYS 120V60HzCODEBWS BWS BWSMONITORS123452 4 6 8 10 12 14 16 18 20 22 24 26
AD1996 System CPU POR TS120V60HzDATA LINE12PROG MON1234 567 8910AD2091 Matrix ControllerB W S B W S B W S B W SDATA LINEINOUTINOUT12CODESELEC T12PW
CAMERA NUMBER SEQUENCEA4Camera SwitchNumber SettingTens Units1 0 1 Group 12 0 2 Group 13 0 3 Group 14 0 4 Group 15 0 5 Group 16 0 6 Group 17 0 7 Group
CAMERA NUMBER SEQUENCEA5Camera SwitchNumber SettingTens Units257 0 1 Group 5258 0 2 Group 5259 0 3 Group 5260 0 4 Group 5261 0 5 Group 5262 0 6 Group
CAMERA NUMBER SEQUENCEA6Camera SwitchNumber SettingTens Units385 0 1 Group 7386 0 2 Group 7387 0 3 Group 7388 0 4 Group 7389 0 5 Group 7390 0 6 Group
CAMERA NUMBER SEQUENCEA7Camera SwitchNumber SettingTens Units577 0 1 Group 10578 0 2 Group 10579 0 3 Group 10580 0 4 Group 10581 0 5 Group 10582 0 6 G
Table of ContentsDESCRIPTION ... 1ROUTINE M
CAMERA NUMBER SEQUENCEA8Camera SwitchNumber SettingTens Units641 0 1 Group 11642 0 2 Group 11643 0 3 Group 11644 0 4 Group 11645 0 5 Group 11646 0 6 G
CAMERA NUMBER SEQUENCEA9Camera SwitchNumber SettingTens Units769 0 1 Group 13770 0 2 Group 13771 0 3 Group 13772 0 4 Group 13773 0 5 Group 13774 0 6 G
Camera SwitchNumber SettingTens Units961 0 1 Group 16962 0 2 Group 16963 0 3 Group 16964 0 4 Group 16965 0 5 Group 16966 0 6 Group 16967 0 7 Group 169
PROBLEM CHECKLISTUnit does not respond to power-up tests Check that 24VAC is connected to pins 3 & 5 of 7-pin connectorAfter power on tests, unit
ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Backlash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.65"/245 mm11.25"/285.75 mm 4.5"114.3 mm24"/609.6 mm10.9"/277 mmDIMENSIONSA13
MODELS:AD1273/B10C: Smoked Dome, B/W camera, 10X zoomlens, for drop or hard ceiling mountAD1273/C10C: Smoked Dome, Color Camera, 10xZoom Lens, for dro
AD1273 DESCRIPTIONDESCRIPTIONThe AD1273 CobraDome Indoor Surveillance unit is designedfor applications requiring a precision, high-speed pan/tiltmecha
COMPONENT IDENTIFICATIONCHASSIS HOUSINGThe CHASSIS HOUSING contains the major componentsof the AD1273 CobraDome. Also, all mounting hardware isattache
3AD1273 COMPONENT IDENTIFICATIONBNC ConnectorFascia MountingSnap Receptacle (4)Chassis to Housing Mounting Pin (2 each side)Lower Dome Mounting Snap